Life Safety Systems Maintenance of the fire alarms, sprinklers, extinguishers, emergency lighting and smoke vents is to be up to date and compliant Service providers will need to be diligent when reinstating systems and services such as electrical services and domestic water systems as they cannot simply be reinstated without checks and balances being in place prior to reoccupation. Review of systems which could be changed to be ‘contactless’ where possible such as lighting systems, sensor-activated faucets and toilets, water dispensers and smart windows shades. Non-Domestic Water Systems Chilled water, condenser water, low temperature hot water systems to undergo microbiological and chemical sampling if they have been operated at below 50% of their normal operating levels Domestic Water Services Undertake legionella and TVC sampling of the hot and cold water outlets, undertake clean and chlorination of systems if required, review stored water capacity in line with occupancy levels Vertical Transportation Statutory LOLER Inspections to be in date for lifts and escalators Heating and Cooling systems All systems are fully certified operational and set to appropriate season settings. Ventilation Systems Increased air exchange, improved filtration systems and servicing frequency where possible replace filters. (Air handling units and terminal units such as FCUs, VAVs etc.) General Electrical and Mechanical Services Prioritise backlog maintenance and carry out repairs as required Building Systems – Pre Occupation inspections and enhanced maintenance As we prepare to adapt provisions for reoccupation of properties we need to ensure the fundamental services and compliance testing have been undertaken and buildings are fit and ready for occupation. All statutory compliance checks, maintenance and testing should be reinstated and where possible enhanced to pre Covid-19 frequencies prior to reoccupation of the property to mitigate the risk of occupier health, wellbeing, safety and system failure. Any enhancement of a building's mechanical services provision is likely to impact on that property's environmental, social and governance (ESG) strategy. There will need to be a trade off, for example, for enhacing the fresh air supply and the wellbeing benefits this will bring against the increase in energy costs for that provision. This will include but not limited to the following mechanical, electrical, public health and vertical transportation systems: Reoccupation plans of tenants will need to incorporated into base building mobilisation programs to ensue robust protocols and service levels are in place and increased as occupation levels increase. These new procedures and guidance will become the new normal, balancing safety and wellbeing for employees, visitors and vendors with business requirements and changes to operating principles. SAVILLS OFFICE FiT Adapt, Evolve, Improve | Landlord/FM Engagement | 17 16
Made with FlippingBook
RkJQdWJsaXNoZXIy NTcyOTU=